 ====Background Information==== ====Background Information====
- +\\  
-After combining the Schmitt trigger and the integrator, the circuit generates a periodic signal with a fixed duty cycle. For many PWM applications, however, it is necessary to adjust the duty cycle in order to control the average power delivered to the load. In the case of an LED, changing the duty cycle directly affects the perceived brightness. Therefore, the oscillator circuit is modified so that the duty cycle can be varied to control the brightness of the LED. +After combining the Schmitt trigger and the integrator, the circuit generates a periodic signal with a fixed duty cycle. For many PWM applications, however, it is necessary to adjust the duty cycle in order to control the average power delivered to the load. \\ 
 +In the case of an LED, changing the duty cycle directly affects the perceived brightness. Therefore, the oscillator circuit is modified so that the duty cycle can be varied to control the brightness of the LED. 
 +\\ 
 ====Experimental Tasks==== ====Experimental Tasks====
 +\\ 
 To analyze how to adjust the duty cycle of the PWM-signal, the following circuit is used:\\  To analyze how to adjust the duty cycle of the PWM-signal, the following circuit is used:\\ 
-\\  
 \\  \\ 
 <wrap left> <wrap left>
 {{drawio>duty_cycle_experiment.svg}} {{drawio>duty_cycle_experiment.svg}}
 </wrap> </wrap>
-\\  +~~CLEARFIX~~
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-\\ +
  
-  - Build the circuit on the MEXLE-board. Connect channel 1 of the oscilloscope to TR and channel 2 to SQ. The duty cycle can be adjusted using R1. Perform the measurements for the minimum, maximum, and midpoint duty-cycle settings with the capacitances **C1 = 10nF** and **C1 = 1nF**. Sketch the oscilloscope screen for each case. \\ \\ \\ **C1 = 10 nF, minimum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$\\ \\ \\ \\ \\ \\ \\ \\    \\ \\ \\ **C1 = 10 nF, maximum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$\\ \\ \\ \\ \\ \\ \\ \\   \\ \\ \\ **C1 = 10 nF, middle position**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$\\ \\ \\ \\ \\ \\ \\ \\    \\ \\ \\ **C1 = 1 nF, minimum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$\\ \\ \\ \\ \\ \\ \\ \\    \\ \\ \\ **C1 = 1 nF, maximum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$\\ \\ \\ \\ \\ \\ \\ \\    \\ \\ \\ **C1 = 1 nF, middle position**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$\\ \\ \\ \\ \\ \\ \\ \\    +  - Build the circuit on the MEXLE-board. Connect channel 1 of the oscilloscope to TR and channel 2 to SQ. The duty cycle can be adjusted using R1. Perform the measurements for the minimum, maximum, and midpoint duty-cycle settings with the capacitances **C1 = 10nF** and **C1 = 1nF**. Sketch the oscilloscope screen for each case. \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\  
-  - Explain how this circuit works in a few sentences. +**C1 = 10 nF, minimum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$ ~~CLEARFIX~~ 
 +\\ **C1 = 10 nF, maximum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$ 
 +~~CLEARFIX~~  
 +\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 
 +\\ **C1 = 10 nF, middle position**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$ 
 +~~CLEARFIX~~  
 +\\ **C1 = 1 nF, minimum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$ 
 +~~CLEARFIX~~  
 +\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 
 +\\ **C1 = 1 nF, maximum duty cycle**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$ 
 +~~CLEARFIX~~  
 +\\ **C1 = 1 nF, middle position**\\ \\ <wrap left>{{drawio>oscilloscope_screen.svg}}</wrap>\\ \\ \\ Channel 1: $\frac {Volt}{Div}=$\\ \\ Channel 2: $\frac {Volt}{Div}=$\\ \\ \\ Time basis: $\frac {T}{Div}=$  
 +~~CLEARFIX~~  
 +\\ \\ \\ \\ \\ \\ \\ 
 +  - Explain how this circuit works in a few sentences. \\  \\  \\  \\  \\  \\  \\  \\  \\  \\ 
  
  
Line 42: Line 36:
 ====Test Questions - Integrator==== ====Test Questions - Integrator====
 </WRAP> </WRAP>
 +~~PAGEBREAK~~