The operation of an OPV in the saturation range can be enforced in the circuit by feeding back the output signal, i.e., returning it to the non-inverting input (+ input). In the circuit shown, the feedback is provided by resistor $R_\mathrm{2}$.

mexlefirst_public:non_inverting_schmitt_trigger_circuit.svg















The output voltage $u_\mathrm{a}$ can only take two values, either $\mathrm{+}U_\mathrm{sat}$ or $\mathrm{-}U_\mathrm{sat}$. It switches between these two values when no voltage drops at the differential input of the OPV, ($u_\mathrm{d}=0$). Then $i_\mathrm{R2}=\frac{u_\mathrm{a}}{R_\mathrm{2}}$ and $u_\mathrm{e}=-R_\mathrm{1} \cdot i_\mathrm{R1}$. Since the OPV input current is $i_\mathrm{p}=0$, the currents through the resistors must be equal, and the following relationship applies for the switching points: $u_\mathrm{e}=-\frac{R_\mathrm{1}}{R_\mathrm{2}}\cdot u_\mathrm{a}=\mp\frac{R_\mathrm{1}}{R_\mathrm{2}}\cdot U_\mathrm{sat}$


mexlefirst_public:non_inverting_schmitt_trigger_characteristic_input_output_signal.svg















The image shows the input/output characteristic curve of the circuit known as a β€œnon-inverting Schmitt trigger.” The reaction to any input signal is shown on the right. The circuit only switches to $\mathrm{+}U_\mathrm{sat}$, when the positive switching threshold at the input is reached. It only switches to $\mathrm{-}U_\mathrm{sat}$, when the negative switching threshold at the input is reached.

To analyze the behavior of the schmitt trigger, the following circuit is used:

mexlefirst_public:schmitt_trigger_circuit_experiment.svg

Supply voltages (from power supply unit):
UCC = + 3V, UEE = - 3V

Values of the components used:
R2 = 20kΩ, R3 = 27kΩ










  1. task-type-result Calculate the switching thresholds using the values given under SETUP.
  2. task-type-oscilloscope Roughly sketch the voltage curves that you expect at the SQ output when you apply a triangular signal to Ue whose amplitude just reaches the switching points.
  3. task-type-image Set up the Schmitt Trigger on the MEXLE-Board. Perform the following measurements on the Schmitt Trigger:
    • Connect channel 1 on the oscilloscope to π‘ˆπ‘’ and channel 2 to SQ.
    • Connect the function generator to the Ue input. Set it to triangle with a frequency of 1kHz and a voltage of 3 V (amplitude).
    • Upload a picture of the oscilloscope screen image.
  4. task-type-freetext Compare your measurement with the calculation from task 1 and the forecast from task 2. Explain your results.
  5. task-type-oscilloscope Sketch the oscilloscope screen image you would expect for 1 V (amplitude).
  6. task-type-freetext Check your results of task 5 by reducing the volstage of the signal generator. Compare and explain the results.